Sign In | Join Free | My himfr.com |
|
Ask Lasest Price | |
Brand Name : | HUA QUN |
Model Number : | AT-RM001 |
Certification : | ISO9001 |
Price : | Pending |
Payment Terms : | L/C, T/T, Western Union |
Supply Ability : | 100 set per month |
Delivery Time : | 7 days |
Retroreflective Performance Measurement For Road Markings
Retroreflectometer With Large Data Storage
Retroreflective Performance Measurement for Road Markings
Retroreflectometer with Large Data Storage
Retroreflectometer for road markings is used to measure the brightness coefficient of line
retroreflection. The main characteristic of its research is to
simulate the brightness of the markings on the road surface when a
motor vehicle is driving at night. After being reflected by the
headlights, the brightness is observed by the driver in the cab,
the measured parameter is the nighttime retroreflection brightness
coefficient, which is the rl value. This instrument is easy to
operate and has reliable measurement values. It is suitable for
both laboratory environments and outdoor on-site measurements. It
is a necessary instrument for production, quality supervision,
engineering construction, supervision and other units to measure
the retroreflecitve performance of road markings.
Main Parameters
Measurement Items | Retroreflection brightness coefficient |
RL Measuring Range | 0-4000 mcd/(㎡. lx ) |
QD Measurement Range ( optional ) | 0-400 mcd/( ㎡. lx) |
Viewing angle | 1.05º |
Incident angle | 88.76º, the complementary angle is 1.24º |
Color temperature | 2856±50K ( Standard A light source ) |
Repeatability measurement error | ≤2% |
Measurement of aperture area | 340mm×95mm |
Working Time | >72h |
Data storage space | 16G (more than 200000 test data ) |
Overall volume | 700mm×135mm×115mm |
Net Weight | 6kg |
Main Features
1. High definition touch screen
2. Imported all aluminum body
3. Real time voice broadcasting of measurement data, on-site
printing of detection data
4. Support for vibration marking testing
5. USB data interface, supporting one click Excel data export
Compliant with Specification
◎ EN 1436 (RL & QD)
◎ ASTM E2302 (QD)
◎ ASTM E2367 (RL)
◎ ASTM E1710
◎ ASTM E2177-18
◎ EN 1436
Introduction to Use
• On/off button
Turn on/off the instrument.
When starting up, press the button for 10-12 seconds, and the
display screen is light. Then there is a “drop” sound, and the
instrument is turned on;
When shutting down, press the button and the instrument is turned
off.Note: When the instrument is turned off, it can be charged by a
standard charger.
• Testing button
Trigger operation when measuring.
Press the button and the instrument begins to test.
• Display screen
Display various states and data information when the instrument is
working, and can also perform system settings, measurement
calibration, and record transmission for the instrument.
• Printer
Print out the current measurement results with the built-in
printer.
• USB interface
Connect the instrument to the computer through USB interface to
transmit data.
•Charging plughole
Charge the instrument.
![]() |